Home

Applications

APPLICATIONS OVERVIEW
DRUG DISCOVERY
ADME-Tox
Biochemical Assays
Cell-based Assays
HTS and Secondary Screening
Microsampling
Protein Crystallography
RNAi
Sample Management
CANCER RESEARCH
Personalized Medicine
Functional Screening / DSRT
RNAi
Sequencing
Single-cell Genomics
GENOMIC RESEARCH
Gene Expression
Genotyping
Microbiome
qPCR
Sequencing
Single-cell Genomics
Synthetic Biology

Products

LIQUID HANDLING
LIQUID HANDLERS OVERVIEW
Echo® 525 Liquid Handler
Echo® 555 Liquid Handler
Echo® 550 Liquid Handler
Echo® 520 Liquid Handler
AUTOMATION
AUTOMATION OVERVIEW
Access™ Laboratory Workstation
Tempo™ Automation Control Software
SOFTWARE APPLICATIONS
SOFTWARE OVERVIEW
Echo® Array Maker
Echo® Cherry Pick
Echo® Combination Screen
Echo® Compliance Manager
Echo® Dose-Response
Echo® Plate Audit
Echo® Plate Reformat
CONSUMABLES
CONSUMABLES OVERVIEW
Echo® Qualified Microplates
Labcyte® Assay Microplates
MicroClime® Environmental Lid
Echo® Qualified Reservoir

Technology

Echo® Acoustic Liquid Handling
Dynamic Fluid Analysis™
Acoustic Mass Spectrometry
Direct Dilution

News / Events

Labcyte BLOG
Upcoming Events
Press Releases
Labcyte in the News
Labcyte Community

Resources

JALA Special Issue
Publications
Articles and Other Media
Application Notes
Posters
Webinars
Videos
Customer Profiles
Core Labs

Support

Brochures
Web Documentation*
User Guides*
Quick Start Guides*
Specification Sheets
Site Prep Guides
Service and Maintenance
Request Information

Company

About Us
Echo® Acoustic Technology
Leadership Team
Meet Labcyte
Careers
Contact and Location
Privacy Policy

ARTICLES and Other Media

featuring the Echo® Acoustic Technology

121 Total Articles and Other Media
HOME | RESOURCES | Articles

ARTICLES

121 Total Articles and Other Media

REFINE YOUR SEARCH



TITLES and AUTHORS Year Link PDF + Abstract
  • Echo Application Highlight Protein Crystallography Labcyte Science

    Institution: Labcyte Inc.

    Publication:

    2012 abstract

    The Echo® liquid handler enables protein crystal formation with sitting drop volumes as little as 50 nL. Nanoliter volumes of protein and crystallography reagents can be transferred into sitting drop wells of crystallography plates. Precise and accurate drop placement eliminates cross-contamination and ensures drop-on-drop placement for blending protein and crystallography solutions. Precise transfer of reagents ensures repeatable crystallization trials. With Dynamic Fluid Analysis™ only a single fluid class setting is needed to transfer all crystallography sparse matrix reagents—eliminating the need for multiple calibrations or repeated optimization of fluid class settings.

    Related Subject:
    Echo Application Highlight Protein Crystallography
    Link:
    https://labcyte.box.com/s/eyztuh28ytz8vp64xge7
  • Miniaturized GloSensor™ cAMP Assay Using the Echo® Liquid Handler Worzella T, Allison T, Stecha P, Kershner K, Cong M, Zimprich C, Cowan C

    Institution: Promega Corp., Labcyte Inc.

    Publication: POSTER

    2012 PDF abstract

    As biological assays used for HTS and uHTS are miniaturized, it is critical to maintain assay sensitivity while minimizing reagent volumes and maximizing throughput. The GloSensor™ cAMP Assay provides an extremely sensitive and easy to use, real-time luminescent assay format for the interrogation of overexpressed or endogenous GPCRs that signal via changes in the intracellular concentration of cAMP. Tipless, touchless transfers with the Echo® liquid handler eliminate the need for costly disposable tips and greatly simplify assay development efforts. Precise and accurate drop placement eliminates cross-contamination. In this work, we demonstrate optimization of the GloSensor cAMP Assay in low-volume format using a stably transfected HEK293 cell line model expressing the melanocortin 4 receptor (MC4R) and a cAMP-sensing variant of firefly luciferase. We show that the Echo liquid handler is able to titrate small molecule and peptide agonists and antagonists, providing robust assay results that are achieved with significantly reduced volumes of cells and compound.

    Publication / Type:
    POSTER
    Related Subject:
    Miniaturized GloSensor™ cAMP Assay Echo® Liquid Handler
  • Pharmacological Evaluation of Different Compound Dilution and Transfer Paradigms on an Enzyme Assay in Low Volume 384-well Format Spicer T, Fitzgerald Y, Burford N, Matson S, Chatterjee M, Gilchrist M, Myslik J, O’Connell J

    Institution: Bristol-Myers Squibb

    Publication: PRESENTATION

    2012 PDF abstract

    Miniaturization of assays to low volume 384-well and 1536-well formats has dramatically reduced HTS cost and improved throughput. However, miniaturization has posed some challenges: 1) The difficulty in accurately transferring nanoliter volumes of compound in 100% DMSO into assay plates 2) The low DMSO tolerance of assays (particularly cell-based assays)

    This has necessitated an aqueous intermediate dilution of compound prior to addition into assay plates. The effect of this aqueous intermediate dilution on compound solubility has often been questioned.

    Recent advances in liquid handling technology has achieved reliable, cost-effective and efficient nanoliter transfer of compound in 100% DMSO into assay plates, improving solubility whilst working within the boundary of DMSO tolerance for the assay. Miniaturization of assays to low volume 384-well and 1536-well formats has dramatically reduced HTS cost and improved throughput.

    DMSO, IC50, direct dilution, serial dilution, miniaturization, dose-response

    Publication / Type:
    PRESENTATION
    Related Subject:
    Pharmacological Evaluation of Different Compound Dilution and Transfer Paradigms Enzyme Assay Low Volume 384-well Format
  • Accurate and Precise Low Volume Transfer of Antibody and Enzyme Solutions Stored in Glycerol Using the Echo® Liquid Handler Harris D, Stearns R, Huang R, Glazer C, Lee H, and Datwani S

    Institution: Labcyte Inc.

    Publication:

    2011 PDF abstract

    The lifetime and stability of antibody stock solutions, antibody conjugate solutions and enzymes are increased by the addition of cryoprotectants such as glycerol or ethylene glycol. Solutions containing glycerol have historically been problematic to dispense with traditional tip-based liquid handlers. Increased solution viscosity and sample sticking reduces pipetting accuracy and precision, which can be especially significant in nanoliter volume transfers.

    The Echo 555 liquid transfer (Labcyte Inc., Sunnyvale, CA) is a completely touchless acoustic transfer technology that can precisely and accurately transfer fluids, including glycerol stock solutions (0-60%). Nanoliter volume transfers were confirmed with a fluorescent marker dye and standard curve for a range of glycerol concentrations. The Echo liquid handler was used to dispense alkaline phosphatase (stored in 50% glycerol) in a traditional phosphatase assay with p-Nitrophenyl phosphate (pNPP) as the substrate with expected activity results. Further experiments showed that a variety of ELISA, kinase, cyclic AMP and cytokine assay kit components can also be transferred using the Echo liquid handler with excellent volumetric accuracy and precision.

    The results of these applications illustrate the new capabilities of the Echo liquid handler to enable assay setup, reduce reaction volume resulting in reagent and consumables savings with higher throughput.

    Related Subject:
    Accurate Precise Low Volume Antibody Enzyme Glycerol Echo® Liquid Handler
  • High-Throughput, Low Volume, siRNA Screening Labcyte Science

    Institution: Labcyte Inc.

    Publication:

    2011 PDF abstract

    The POD™ automation platform utilizes the revolutionary Echo® liquid handler and Echo® software applications to produce low volume assay plates for siRNA screening with unmatched precision and accuracy. Using lower quantities of siRNA and assay reagents makes the POD system the most cost-effective solution for target identification and validation. This highlight reviews the outcome of a study comparing the knock-down of gene expression after siRNA transfection followed by reporter gene and cell viability assays.

    Related Subject:
    High-Throughput Low Volume siRNA Screening
  • Miniaturization of One-Step Gene Expression Using the Access™ Laboratory Workstation and the Echo® Liquid Handler Dyer R, Glazer C, Allison T, Datwani S, Barco J

    Institution: Labcyte Inc.

    Publication:

    2011 PDF abstract

    Quantitative PCR (qPCR) is a powerful tool used for genotyping, SNP analysis, and gene-expression studies. Quantitative detection of small mRNA expression changes facilitates the characterization of early-stage cancer and infectious disease. Advances in qPCR technology to enable the use of high density 384- and 1536-well microplates have led to a demand for automation and miniaturization of qPCR preparation. With automation, researchers can generate larger sets of data quickly, while minimizing resource burden and improving reproducibility across assays. As researchers push further toward miniaturization, potential cost savings are met with high risk for cross contamination, lower precision, and poor accuracy. The Access workstation relies on the Echo liquid handler and its tipless, touchless transfer of samples and reagents to eliminate such risks—providing high quality assay-ready plates. This poster examines the ability to automate qPCR assay preparation from lysis to analysis while reducing overall reaction volumes to as little as 250 nL.

    Related Subject:
    Miniaturization One-Step Gene Expression Access™ Laboratory Workstation Echo® Liquid Handler
  • Miniaturization of 1536-Well Quantitative PCR Using the Echo® Liquid Handler Glazer C, Lee H, Datwani S, Sonntag M, Jarman C, Pickett S

    Institution: Labcyte Inc.

    Publication: real-time PCR, rt-PCR, lysis, one-step,  cost reduction, ALA 2011

    2011 PDF abstract

    Miniaturized quantitative PCR (qPCR) in 1536-well plates holds great promise for increased throughput and reagent savings. Delivering reagents to high-density plates can be challenging for conventional tip-based liquid handling systems, leading to inaccurate assay volumes and contamination errors across wells. This study utilized the Labcyte Echo 555 liquid handler to prepare miniaturized qPCR reactions in total reaction volumes ranging from 250 nL to 1.0 µL. The resulting amplification curves yielded excellent crossing point precision and accuracy, with coefficients of variation ranging from 0.95 to 1.25%. Tests with positive and negative controls dispensed into alternating wells revealed zero cross-contamination. These results demonstrate the Echo liquid handler as an ideal platform for preparing miniaturized qPCR reactions in a 1536-well plate format.

    Publication / Type:
    real-time PCR, rt-PCR, lysis, one-step,  cost reduction, ALA 2011
    Related Subject:
    Miniaturization 1536-Well Quantitative PCR Echo® Liquid Handler
  • 300 Nanoliter qPCR in a One-Step Process from Cells to Cp Utilizing the Echo® Liquid Handler Glazer C, Lee H, Datwani S, Sonntag M

    Institution: Labcyte Inc.

    Publication: quantitative PCR, real-time PCR, rt-PCR, cost reduction, SBS 2011

    2011 PDF abstract

    Recent innovations in cell lysis reagents and high throughput quantitative PCR miniaturization have allowed researchers to increase throughput while decreasing labor and reagent costs. To ensure high quality data, the liquid handling employed in such low-volume reactions must be precise and accurate. This study utilized the Echo 555 liquid handler (Labcyte Inc., Sunnyvale, CA), the Real-time ready Cell Lysis kit and the LightCycler® 480 system (Roche Applied Science).  Cells were grown in tissue culture plates, lysed with the Real-time Lysis solution and then transferred in nanoliter quantities using the Echo liquid handler into 384-well qPCR plates.  The plates were then cycled in the LightCycler and the resulting amplification analyzed.  Results show excellent standard deviations of less than 0.5 and coefficient of variations of less than 1.5% with volumes as low as 300 nanoliters. The results for this application illustrates the new capabilities of the Echo liquid handler to enable assay setup and reduce reaction volumes resulting in reagent and consumables savings with higher throughput.

    Publication / Type:
    quantitative PCR, real-time PCR, rt-PCR, cost reduction, SBS 2011
    Related Subject:
    300 Nanoliter qPCR Cells Cp Echo® Liquid Handler
  • Miniaturized Gene Expression in as Little as 250 nL Labcyte

    Institution: Labcyte Inc.

    Publication:

    2011 PDF abstract

    The Access™ laboratory workstation presents exciting new capabilities for walkaway assay assembly and screening of high-throughput gene expression analysis using qPCR. The Access workstation combines the Echo® liquid handler, the Roche® RealTime ready Cell Lysis Kit and the Roche LightCycler® 480 system into a single automated system for gene expression assays with reaction volumes as low as 250 nL. With flexible, wizard-driven software and high quality acoustic liquid transfer, the Access workstation is an ideal platform for both assay development and screening with zero cross contamination.

    Related Subject:
    Miniaturized Gene Expression
  • Acoustic, Touchless, Transfer of Compounds, Proteins and Protein Crystallography Fluids for Crystallographic Screening Stearns R, Huang R, Harris D, Ellson R, Olechno J, Datwani S

    Institution: Labcyte Inc.

    Publication:

    2011 PDF abstract

    Recent advances in X-ray sources are rapidly reducing the sample size and exposure time for protein crystal structure determination.  In order to fully exploit the reduced sample requirement for creating protein crystals we present an accurate and precise methodology for transferring nanoliter volumes of these solutions using the Echo® liquid handler.

    Typical protein crystallization solutions have large variations in both viscosity and salt concentration and often have detergents or other additives.  These solutions exhibit a broad range of rheological and acoustical properties.  We show that the wide variety of aqueous-based fluids commonly used by the protein crystallography community is readily transferred with the Echo 555 liquid handler even within the broad viscosity range of 1-15 cP.  The Echo liquid handler provides the user with a single calibration covering the gamut of protein crystallography solutions. The instrument uses acoustic energy to rapidly and automatically analyze each crystallographic solution just prior to transfer to optimize nanoliter-scale droplet transfer, responding to the state of the crystallographic solution at that instant in time.  Results will be presented demonstrating the high precision and accuracy of transfers of binary mixtures of glycerol/water.  Additionally, the Echo liquid handler has been used to transfer protein microcrystals to micromesh mountings and the resulting X-ray structures yield high resolution.

    The results illustrate new capabilities of the Echo liquid handler that enable in situ optimization of protein crystallography conditions and volume miniaturization to match recent advancements in laser technology.

    Related Subject:
    viscous, viscosity, PEG, "organic solvents", buffers, salt, glycerol, assay development and optimization
EXPAND ABSTRACTS




Featured Labcyte Downloads
For Research Use Only Not for use in Diagnostics
TOP