Echo QUALIFIED MICROPLATES

The best acoustic liquid transfer comes from the best microplates

REQUEST SAMPLE Echo Qualified Microplates

Echo Qualified Microplates

The best acoustic liquid transfer comes from the best microplates. Echo Liquid Handlers are designed to use Labcyte 384-well and 1536-well source microplates for precise and accurate liquid transfer.

Labcyte Echo Qualified Microplates deliver the best possible results in compound storage and miniaturized assays. Each plate is insured to meet the exacting specifications required for consistent acoustic transfer. Labcyte performs functional qualification tests on each microplate lot with an Echo Liquid Handler to verify that our microplates enable superior acoustic transfer precision and accuracy and DMSO hydration measurements.

Precise manufacturing and qualification requirements deliver high quality results and data

Key Features

  • Designed for use with Echo Liquid Handling Systems
  • Made of cyclic olefin copolymer or polypropylene
  • Enables high precision transfers for broad volume ranges
  • High accuracy and linearity of DMSO hydration measurements
  • Lot tested to meet Echo specifications
  • Low intra- and inter-plate CVs
  • Available with tissue-culture surface treatment

Echo qualified microplates are available with low dead volume, custom barcode, or sterile options. Contact your Labcyte sales representative for more detail

Product Specifications

Type Specifications Catalog #Cat. # Units 525 55X
Echo Qualified 384-Well Polypropylene Microplate 2.0** (384PP 2.0) Standard
Sterile
Tissue Culture
55X
Flat bottom, TRANSLUCENT
DMSO working range: 15-65 μL
Buffer working range: 15-65 μL*
(includes buffers with and without protein or detergents, and containing up to 50% glycerol)
Protein crystallography reagents: 20–50μL* * Expanded range in newer Echo models; not all aqueous transfer capabilities are available for all instrument models. ** Software requirement - The Echo Qualified 384PP 2.0 microplate cannot be used on Echo instruments that do not have the software upgrade. The required Echo software version is 2.4.10 or 2.5.10 or later.
Standard
Sterile
Tissue Culture
PP-0200
PP-0200-BC
PPS-0200
PPS-0200-BC
PPT-0200
100/case
Echo Qualified 384-Well Polypropylene 2.0 Plus Microplate (384PP 2.0 Plus) Standard (Sterile) 525 Flat bottom, CLEAR
Buffer working range: 15-50μL
Buffer/protein working range: 15-65μL
Standard (Sterile) PPL-0200 100/case
Echo Qualified 384-Well Low Dead Volume Microplate(384LDV) Standard
Sterile
55X
Flat bottom, CLEAR
DMSO working range: 2.5–12 μL
Buffer working range: 3–12 μL*
Buffer/protein working range: 6–14 μL*
* Not all aqueous transfer capabilities are available for all instrument models
Standard
Sterile
LP-0200
LP-0200-BC
LPS-0200
50/case
Echo Qualified 384-Well Low Dead Volume Microplate (384LDV-Black) Standard 55X Flat bottom, BLACK
DMSO working range: 2.5–12 μL
Buffer working range: 3–12 μL*
Buffer/protein working range: 6–14 μL*
* Not all aqueous transfer capabilities are available for all instrument models
Standard LP-0210
LP-0210-BC
50/case
Echo Qualified 384-Well Low Dead Volume Plus Microplate(384LDV Plus) Standard 525 Flat bottom, CLEAR
Buffer working range: 4.5 – 14 μL
Buffer/protein working range: 4.5 – 14 μL
Standard (Sterile) LP-0200 50/case
Echo Qualified 1536-Well Low Dead Volume Microplate (1536LDV) Standard 55X Flat bottom, CLEAR
DMSO working range: 1.0–5.5 μL
Standard LP-0400
LP-0400-BC
50/case
Echo Qualified 1536-Well Low Dead Volume Microplate (1536LDV Black) Standard 55X Flat bottom, BLACK
DMSO working range: 1.0–5.5 μL
Standard LP-0410
LP-0410-BC
50/case
Echo Qualified 1536-Well Low Dead Volume Microplate, Tissue Culture Treated (1536LDV-TC) 1536LDV-TC
1536LDV TC Collagen
55X
Flat bottom, CLEAR
DMSO Working range: 1.5–5 μL
1536LDV-TC
1536LDV TC Collagen
LPT-0400
LPT-0400-CA
50/case